PLC & SCADA Jobs

PLC stands for Programmable Logic Controller and it is a term used in automating electro-mechanical processes. SCADA is an abbreviation for supervisory control and data acquisition. It refers to industrial control systems where computers monitor or control a process. If your business needs help with PLC / SCADA then you can hire the help of talented PLC / SCADA freelancers on this site. Start by posting your job today.

Hire PLC & SCADA Programmers

Filter

My recent searches
Filter by:
Budget
to
to
to
Type
Skills
Languages
    Job State
    8 jobs found, pricing in NZD

    Existing hardware (used, ca. 2000-2005): ================================= - LinMot Servo Controller E100-AT, Firmware 1.3.14 (Art. No. 0150-1601) - LinMot Power Supply S01-48/150 (Art. No. 0150-1940) - Linmot Actuator * Stator P01-23x160-D100 (Art. No. 0150-1202) * Slider PL01-12x420/370 (Art. No. 0150-1324) - Arduino Mega 2560 R3 with RS232 shield Documentation of ASCII protocol: =========================== Goals: ====== 1. Finalize design and wiring for a control box employing - Arduino Mega 2560 with RS232 shield - push buttons, potentiometers, rotary encoders, status LEDs, digital displays 2. Write Arduino code making use of the E100-AT RS232 ASCII protocol to: - display operating states of E100-AT servo controller via status LEDs on the control box (SETUP, WAIT FOR DISA...

    $1215 (Avg Bid)
    $1215 Avg Bid
    20 bids

    The project is to replace an obsolete simovert drive and micromaster drive with MM440 drive.

    $879 (Avg Bid)
    $879 Avg Bid
    17 bids

    We are looking for some one to program Comfort Panel TP 900 Data logging and Online Report Printing on Dot Matrix Printer

    $292 (Avg Bid)
    $292 Avg Bid
    3 bids

    Controlling up to 4 pumps selectable on LOGO HMI. Pressure setpoint (HMI Setpoint) will be used to control the pumps. The system will start with 1 pump and if setpoint is not met at full speed the second pump will come online and so on till the 4th to maintain the set pressure. Duty rotation is required on all pumps, pump run hours is required to know how long the pump has been running such that when the set rotation hours are reached (set on HMI). Each pump require a run signal as well as analogue 4-20 mA speed setpoint. Each pump has a fault signal that will show the status of the pump on the HMI. If the pressure does not increase after a delay (5 second set on HMI) speed change, the speed should be dropped slowly and if the pressure does not change switch off the pump but if the pressu...

    $355 (Avg Bid)
    $355 Avg Bid
    26 bids
    PLC Winder 2 days left

    We need the following equations for winding yarn on a winder: Cylinder speed Growth diameter Guide cylinder speed The machine is a winder that has a cylinder where tubes with a diameter of 0.107 m are inserted, and a slotted cylinder that acts as a guide and gives the angle. The angles, speed of entry to the machine, cylinder diameters are known. PLC program

    $771 (Avg Bid)
    $771 Avg Bid
    18 bids

    I have a home that the previous seller set up with PLC to control the sprinklers, pool fill, pool heater, and pool fill. It is controlled by Direct Logic 06 Koyo. It had been working fine as it was being run by a server in Canada. The previous owner cancelled that service and now the system does not work on its own. Wanting to see if we can have it run locally on its own without needing the server?

    $315 (Avg Bid)
    $315 Avg Bid
    11 bids
    PLC communication 1 day left
    VERIFIED

    I buyed a machine with PLC controller and a XINJE TG765S-XT Touchwin panel without rj port (just rs232). I need to integrate the information flows of the machine into my company ERP. I want to send commands to machine (start, configuration ...) and receive a log (number of pieces produced, operating time between one start and another). The project: 1) replace the panel with another one equipped with an rj45 or connect a ethernet gateway to rs232 port 2) Modify the software on board to communicate via ethernet with the PLCs using a standard protocol (modsbus tcp, OPC UA, MQTT ...) by sending configurations to the machine and receiving the logs

    $1909 (Avg Bid)
    $1909 Avg Bid
    24 bids

    Need setup sql trigger email and sms from intouch wonderware , Fixing values showing 65535 as negative value

    $45 (Avg Bid)
    $45 Avg Bid
    4 bids